IO modules BOX series

  • Modbus RTU IO modules
  • Compatible with IPLOG & LAN-RING
  • A wide range of digital and analog inputs and outputs
  • Highly durable hardware with integrated surge protectors
  • Mounting on a flat surface or DIN35
  • Operating temperature from −40°C to +70°C

The IO modules are Modbus RTU Slave devices and can therefore be easily connected to any Modbus RTU Master device. Typical examples are IPLOG-Gx PLCs and LAN-RING industrial switches. Inputs and outputs can be controlled using Modbus RTU protocols. The industrial design with integrated surge protection for all inputs and outputs guarantees reliable operation even in very demanding conditions. The IO modules are designed for installation on a DIN35 rail or on a flat substrate.

The devices are developed and manufactured in the EU and comply with NDAA requirements.

Models

Interface (IF module):

? ?

Inputs:

? ? ? ? ? ? ?

Outputs:

? ? ? ? ? ? ? ?

AI8.1-05-BOX

1x RS485, 2x 10-bit alarm/digital input (5V), 8x 12-bit analog U/I inputs, 2x NOC 24 V relay outputs, 2x NO 230 V relay outputs

Order code: 5000-0207

Availability: Full-scale production

AI8.1-01-BOX

2x RS485, 8x 12-bit analog U/I inputs, 2x NOC 24 V relay outputs, 2x NO 230 V relay outputs

Order code: 5000-0201

Availability: Full-scale production

AI8.1-01G-BOX

2x RS485, galvanic isolation, 8x 12-bit analog U/I inputs, 2x NOC 24 V relay outputs, 2x NO 230 V relay outputs

Order code: 5000-0202

Availability: Full-scale production

AI8.1-17G-BOX

1x RS485, 1x RS232 (Rx, Tx), galvanic isolation, 8x 12-bit analog U/I inputs, 2x NOC 24 V relay outputs, 2x NO 230 V relay outputs

Order code: 5000-0222

Availability: Full-scale production

AI4.1-05-BOX

1x RS485, 2x 10-bit alarm/digital input (5V), 4x 24-bit analog RTD inputs, 4x SSR outputs, 4x 24 V digital inputs

Order code: 5000-0307

Availability: Full-scale production

AI4.1-01-BOX

2x RS485, 4x 24-bit analog RTD inputs, 4x SSR outputs, 4x 24 V digital inputs

Order code: 5000-0301

Availability: Full-scale production

AI4.1-01G-BOX

2x RS485, galvanic isolation, 2x 10-bit alarm/digital input (5V), 4x 24-bit analog RTD inputs, 4x SSR outputs, 4x 24 V digital inputs

Order code: 5000-0302

Availability: Full-scale production

AI4.1-17G-BOX

1x RS485, 1x RS232 (Rx, Tx), galvanic isolation, 4x 24-bit analog RTD inputs, 4x SSR outputs, 4x 24 V digital inputs

Order code: 5000-0322

Availability: Full-scale production

BI8.1-05-BOX

1x RS485, 8x 10-bit alarm/digital 5 V inputs, 5x digital 5 V inputs, 1x NOC 24 V relay output, 2x open collector NPN outputs

Order code: 5000-0407

Availability: Full-scale production

BI8.1-01-BOX

2x RS485, 8x 10-bit alarm/digital 5 V inputs, 3x digital 5 V inputs, 1x NOC 24 V relay output, 2x open collector NPN outputs

Order code: 5000-0401

Availability: Full-scale production

BI8.1-01G-BOX

2x RS485, galvanic isolation, 8x 10-bit alarm/digital 5 V inputs, 3x digital 5 V inputs, 1x NOC 24 V relay output, 2x open collector NPN outputs

Order code: 5000-0402

Availability: Full-scale production

BI8.1-17G-BOX

1x RS485, 1x RS232 (Rx, Tx), galvanic isolation, 8x 10-bit alarm/digital 5 V inputs, 3x digital 5 V inputs, 1x NOC 24 V relay output, 2x open collector NPN outputs

Order code: 5000-0422

Availability: Full-scale production

RE8.1-05-BOX

1x RS485, 2x 10-bit alarm/digital input (5V), 8x NO 230 V relay outputs, 3x optically isolated 230 V inputs, 2x NOC 230 V relay outputs

Order code: 5000-0507

Availability: Full-scale production

RE8.1-01-BOX

2x RS485, 8x NO 230 V relay outputs, 3x optically isolated 230 V inputs, 2x NOC 230 V relay outputs

Order code: 5000-0501

Availability: Full-scale production

RE8.1-01G-BOX

2x RS485, galvanic isolation, 8x NO 230 V relay outputs, 3x optically isolated 230 V inputs, 2x NOC 230 V relay outputs

Order code: 5000-0502

Availability: Full-scale production

RE8.1-17G-BOX

1x RS485, 1x RS232 (Rx, Tx), galvanic isolation, 8x NO 230 V relay outputs, 3x optically isolated 230 V inputs, 2x NOC 230 V relay outputs

Order code: 5000-0522

Availability: Full-scale production

AO8.1-05-BOX

1x RS485, 2x 10-bit alarm/digital input (5V), 8x 12-bit analog outputs, 4x 12-bit analog voltage inputs, 4x digital 24 V inputs

Order code: 5000-0607

Availability: Full-scale production

AO8.1-01-BOX

2x RS485, 8x 12-bit analog outputs, 4x 12-bit analog voltage inputs, 4x digital 24 V inputs

Order code: 5000-0601

Availability: Full-scale production

AO8.1-01G-BOX

2x RS485, galvanic isolation, 8x 12-bit analog outputs, 4x 12-bit analog voltage inputs, 4x digital 24 V inputs

Order code: 5000-0602

Availability: Full-scale production

AO8.1-17G-BOX

1x RS485, 1x RS232 (Rx, Tx), galvanic isolation, 8x 12-bit analog outputs, 4x 12-bit analog voltage inputs, 4x digital 24 V inputs

Order code: 5000-0622

Availability: Full-scale production

PP8.1-05-BOX

1x RS485, 8x PUSH-PULL transistor outputs, 4x 24V digital inputs, 5x 10-bit alarm/digital 5V inputs, 1x NOC 24V relay output

Order code: 5000-0707

Availability: Full-scale production

PP8.1-01-BOX

2x RS485, 8x PUSH-PULL transistor outputs, 4x 24V digital inputs, 3x 10-bit alarm/digital 5V inputs, 1x NOC 24V relay output

Order code: 5000-0701

Availability: Full-scale production

PP8.1-01G-BOX

2x RS485, galvanic isolation, 8x PUSH-PULL transistor outputs, 4x 24V digital inputs, 3x 10-bit alarm/digital 5V inputs, 1x NOC 24V relay output

Order code: 5000-0702

Availability: Full-scale production

PP8.1-17G-BOX

1x RS485, 1x RS232 (Rx, Tx), galvanic isolation, 8x PUSH-PULL transistor outputs, 4x 24V digital inputs, 3x 10-bit alarm/digital 5V inputs, 1x NOC 24V relay output

Order code: 5000-0722

Availability: Full-scale production

DI8.1-05-BOX

1x RS485, 2x 10bit alarm/digital input (5V), 8x 24V digital inputs, 4x NO 230V relay outputs, 2x PUSH-PULL transistor outputs

Order code: 5000-0107

Availability: Full-scale production

DI8.1-01-BOX

2x RS485, 8x 24 V digital inputs, 4x NO 230 V relay outputs, 2x PUSH-PULL transistor outputs

Order code: 5000-0101

Availability: Full-scale production

DI8.1-01G-BOX

2x RS485, galvanic isolation, 8x 24 V digital inputs, 4x NO 230 V relay outputs, 2x PUSH-PULL transistor outputs

Order code: 5000-0102

Availability: Full-scale production

DI8.1-17G-BOX

1x RS485, 1x RS232 (Rx, Tx), galvanic isolation, 8x 24 V digital inputs, 4x NO 230 V relay outputs, 2x PUSH-PULL transistor outputs

Order code: 5000-0122

Availability: Full-scale production

BO8.1-05-BOX

1x RS485, 8x 8-bit alarm outputs, 5x 10-bit alarm/digital 5V inputs, 1x NOC 24V relay output, 2x open collector NPN outputs

Order code: 5000-0807

Availability: Full-scale production

BO8.1-01-BOX

2x RS485, 8x 8-bit alarm outputs, 3x 10-bit alarm/digital 5V inputs, 1x NOC 24V relay output, 2x open collector NPN outputs

Order code: 5000-0801

Availability: Full-scale production

BO8.1-01G-BOX

2x RS485, galvanic isolation, 8x 8-bit alarm outputs, 3x 10-bit alarm/digital 5V inputs, 1x NOC 24V relay output, 2x open collector NPN outputs

Order code: 5000-0802

Availability: Full-scale production

BO8.1-17G-BOX

1x RS485, 1x RS232 (Rx, Tx), galvanic isolation, 8x 8-bit alarm outputs, 3x 10-bit alarm/digital 5V inputs, 1x NOC 24V relay output, 2x open collector NPN outputs

Order code: 5000-0822

Availability: Full-scale production

RE8.2-05-BOX

1x RS485, 2x 10-bit alarm/digital input (5V), 8x NOC 24 V relay outputs

Order code: 5000-1007

Availability: Full-scale production

RE8.2-01-BOX

2x RS485, 8x NOC 24 V relay outputs

Order code: 5000-1001

Availability: Full-scale production

RE8.2-01G-BOX

2x RS485, galvanic isolation, 8x NOC 24 V relay outputs

Order code: 5000-1002

Availability: Full-scale production

RE8.2-17G-BOX

1x RS485, 1x RS232 (Rx, Tx), galvanic isolation, 8x NOC 24 V relay outputs

Order code: 5000-1022

Availability: Full-scale production

BI8.4-05-BOX

1x RS485, 8x 10-bit alarm/digital 5 V inputs, 4x NOC 24 V relay output, 2x digital 5 V inputs

Order code: 5000-1307

Availability: Full-scale production

BI8.4-01-BOX

2x RS485, 8x 10-bit alarm/digital 5 V inputs, 4x NOC 24 V relay output

Order code: 5000-1301

Availability: Full-scale production

BI8.4-01G-BOX

2x RS485, galvanic isolation, 8x 10-bit alarm/digital 5 V inputs, 4x NOC 24 V relay output

Order code: 5000-1302

Availability: Full-scale production

BI8.4-17G-BOX

1x RS485, 1x RS232 (Rx, Tx), galvanic isolation, 8x 10-bit alarm/digital 5 V inputs, 4x NOC 24 V relay output

Order code: 5000-1322

Availability: Full-scale production

Specifications

Technical parameters
POWER
Input voltage range10 - 60 VDC
ENVIRONMENT AND SURGE PROTECTIONS
I/O surge protectionsMin. 600 W (10/1000 µs)
Operating temperature–40…+70 °C
Storage temperature–40…+70 °C / Max. 95 % humidity
12-BIT ANALOG CURRENT OR VOLTAGE INPUTS (with galvanic isolation)
Voltage ranges±2.5V, ±5V, ±10V, 0V to 5V, 0V to 10V
Current ranges0 to 20mA, 4 to 20mA
Sampling rate1 kSps (adaptive)
24-BIT RTD INPUTS
Resistive rangesPT100, PT1000 (3-wires connection)
Sampling rate1 kSps
Isolation voltage1.000 VRMS (RTDx / CPU)
SSR OUTPUTS
Output typeMOSFET (SPST contact type)
Voltage / current75 VAC to 264 VAC, 45 to 65 Hz / Max. 1 A, minimal 20 mA
Breakdown voltage3.000 Vrms (Input / Output)
Isolation voltage between SSR outputs1.500 Vrms
24 V DIGITAL INPUTS (with galvanic isolation 2.500 Vrms between inputs and CPU)
Input voltage DC / AC | Input currentLog. 0: −30 V to 5 V, Log. 1: +15 V to 30 V | 12 mA at 24 VDC
Maximum input voltage50 V / 1 s
NOC 24 V RELAY OUTPUTS (changeover contact)
Max. load0.5 A / 120 VAC, 1 A / 24 VDC (resistive load)
Electrical lifetime3,000,000 operations
Isolation voltage1.000 Vrms / 1 min. (terminals to electronic or case)
NO 230 V RELAY OUTPUTS (normal open contact)
Max. load5 A / 250 VAC, 3 A / 30 VDC (resistive load)
Electrical lifetime100,000 operations at 250 VAC / 5A
Isolation voltage2.500 Vrms / 1 min. (terminals to electronic or case)
NOC 230 V RELAY OUTPUTS (changeover contact)
Max. load10 A / 250 VAC, peak 15 A, (resistive load)
Electrical lifetime50.000 operations, minimal value
Isolation voltage2.500 Vrms / 1 min. (terminals to electronic or case)
ALARM / 5 V DIGITAL INPUTS
Alarm / digital mode usagePIR / tampers (input voltage max. 7VDC)
Dry contact schematicLog. 0: open, Log. 1: close to ground
Alarm mode rangeFrom 10 to 30.000 Ω (10-bit resolution)
5 V DIGITAL INPUTS
Input voltageMax. 7 VDC
Dry contact schematicLog. 0: open, Log. 1: close to ground
OPEN COLLECTOR NPN TRANSISTORS OUTPUTS
Internal Pull-Up1,000 Ω, ON/OFF by a DIP switch
Maximum load (sinking | sourcing)16 V / 250 mA | 12 V / 1 mA
8-BIT ALARM OUTPUTS
Adjustable range200 to 50 000 Ω
PUSH-PULL TRANSISTOR OUTPUTS
Output typeOpen collector NPN or PNP, Push-Pull (software selectable)
Maximum load30 V / 0.25 A
Galvanic isolation2.500 VRMS (PP x output / CPU)
Shortcut protectionYes (polyswitch)
230 V DIGITAL INPUTS
Input voltage ACLog. 0: 0 VAC to 120 VAC, Log. 1: 200 VAC to 250 VAC
Isolation voltage2.500 Vrms, (IN x / CPU)
Standards and protocols, EMC and safety
EMC and safety
EN 61000-6-2Immunity - industrial environment
IEEE 1613Environmental and Testing Requirements | Electric Power Substations
EN 50130-4 ed. 2Alarm systems - Part 4: Electromagnetic compatibility
EN 55035EMC of multimedia devices - immunity requirements
EN 55032EMC of multimedia devices - emission requirements
EN 61131-2Programmable control units
EN 62368-1Safety requirements of Information technology equipment
EN IEC 63000The Assessment Of Electrical And Electronic Products With Respect To The ROHS
Standards and protocols
MODBUS RTUSlave

Package contents

  • IO module
  • Mounting kit for mounting the switch on a DIN rail
  • Mounting kit for mounting the switch on a flat surface

Accessories

SHELF-IPLOG

Pull-out design 19", easy installation.

M-xDR

Industrial power supplies.